Application:
Phlogopite mica tapes improved are generally applied directly cover conductors, with mica facing the copper to act the ultimate electrical insulation in event of unexpected fire.
Phlogopite mica tape are solution for all essential and emergency systems when circuit integrity must be maintained during and after a fire. It is recommended solution for cable including:
· Power cables
· Control cables
· Instrumentation cables
· Signaling cables
Technical Data
|
Type
|
Unit
|
H90P32G
|
H100P32G
|
H120P32G
|
H160P32G
|
| Thickness
|
mm
|
0.10±0.015
|
0.11±0.015
|
0.12±0.015
|
0.14±0.02
|
|
Density
|
g/m2
|
135±12
|
155±12
|
180±15
|
216±15
|
|
Mica Content
|
g/m2
|
85±5
|
100±5
|
120±5
|
160±5
|
|
Film content
|
g/m2
|
/
|
/
|
/
|
/
|
|
Glass Content
|
g/m2
|
32±3
|
32±3
|
32±3
|
32±3
|
|
Bond content
|
g/m2
|
18±4
|
23±4
|
28±4
|
29±4
|
|
Tensile strength
|
N/cm
|
>120
|
>120
|
>120
|
>120
|
|
Dielectric strength
|
Kv/layer
|
>1.0
|
>1.2
|
>1.4
|
>1.6
|
Standard Supply:
Standard width: minimum 4mm
Standard length: 330M/pad,500M/pad,1000M/pad
As per required length & dimension for traverse wound spool
Standard core: 76mm ( 120mm optional)
Availability: pads and traverse wound spools with customer’s required dimension
Package:
Moisture-proof PE film + cartons+ fumigation free cases
Acceptable customized packing according to customer’s requirements
Storage:
Proper storage with temperature ≤40℃ and humidity ≥60% with original package.